null
Academic & Research teams save 10%Academics save 10%  ·  universities, colleges & research institutions Apply Now

Edwards E2M18 Two-Stage Rotary Vane Vacuum Pump, 12 cfm 115/200–230V, 1-Ph

$7,386.00

Edwards E2M18 Two-Stage Rotary Vane Vacuum Pump, 12 cfm 115/200–230V, 1-Ph

  • SKU: ED-A36317984
  • UPC: 840215220875

Certificates of Analysis

Request a Document

TELL US WHAT YOU NEED • USUALLY SAME BUSINESS DAY

Loading form…

Ask a Question

PRODUCT & TECHNICAL QUESTIONS • USUALLY SAME BUSINESS DAY

Loading form…

Request Quote
In Stock & Ready To Ship!
Current Stock:Only left:
Frequently Bought Together:

You can use this widget to input arbitrary HTML code into the page. Invalid HTML code may cause issues with the preview pane.

You can use this widget to input arbitrary HTML code into the page. Invalid HTML code may cause issues with the preview pane.

You can use this widget to input arbitrary HTML code into the page. Invalid HTML code may cause issues with the preview pane.

Trust Guard Security Scanned

You can use this widget to input arbitrary HTML code into the page. Invalid HTML code may cause issues with the preview pane.

Description

Two-Stage Rotary Vane Vacuum Pump, 12 CFM, 0.75 mTorr | USA Lab

This high-performance two-stage rotary vane vacuum pump is designed for medium and rough vacuum applications requiring dependable pumping speed, deep vacuum performance, and reliable oil-sealed operation. Delivering up to 12.01 CFM at 60 Hz with an ultimate pressure of 0.75 mTorr, it is well suited for demanding laboratory and industrial vacuum processes.

The pump combines a two-stage oil-sealed rotary vane design with forced-air cooling, an IE2 motor, and IP44 protection for dependable operation. Its DN25 ISO-KF inlet and 15 mm nozzle / 3/4" BSPP outlet provide practical connections for laboratory vacuum systems, while a noise level of approximately 57 dB(A) helps maintain a quieter working environment.

Designed for applications including drying, degassing, filtration, vacuum processing, and foreline service, the pump operates from 100/200 V, 50/60 Hz single-phase power and uses Edwards 45 vacuum oil. Some configurations require hard-wiring, and the mains cable is not included.

12.01 CFM @ 60 Hz 0.75 mTorr Ultimate Pressure 950 W @ 60 Hz DN25 ISO-KF Inlet
High Throughput: Up to 12.01 CFM at 60 Hz and 10.01 CFM at 50 Hz — supports demanding medium and rough vacuum applications.
Deep Vacuum: Reaches 0.75 mTorr ultimate pressure and 11.25 mTorr with gas ballast — providing reliable vacuum performance across varied processes.
Efficient Operation: IE2 motor, IP44 protection, and forced-air coolingsupport dependable operation with reduced maintenance requirements.

Why buy from USA Lab

Expert Support
Expert Support
Engineers & technicians on staff.
Quality First
Quality First
Tested and trusted products.
Fast Fulfillment
Fast Fulfillment
Nationwide 1-2 day shipping.
Warranty & Parts
Warranty & Parts
US-based service & spares.

Why this Two-Stage Rotary Vane Vacuum Pump?

  • High pumping speed — delivers up to 12.01 CFM at 60 Hz for efficient evacuation and throughput in medium and rough vacuum systems.
  • Deep ultimate vacuum — achieves 0.75 mTorr ultimate pressure, with 11.25 mTorr performance when operating with gas ballast.
  • Flexible vacuum connections — DN25 ISO-KF inlet and 15 mm nozzle / 3/4" BSPP female outlet simplify integration with laboratory vacuum equipment.
  • Efficient and protected motor — IE2 motor efficiency and IP44 protection support reliable operation in demanding laboratory environments.
  • Quiet forced-air cooling — approximately 57 dB(A) operating noise and fan-assisted cooling help balance performance with practical laboratory operation.

Talk to an expert

Get help selecting the right vacuum pump configuration, oil volume, gas-ballast setup, and connection accessories for your process.

Call 734-855-4890

Technical Specifications

Specification Details
Pump Type Two-stage oil-sealed rotary vane vacuum pump
Pumping Speed at 60 Hz 12.01 CFM (Air/N2)
Pumping Speed at 50 Hz 10.01 CFM (Air/N2)
Maximum Displacement at 60 Hz 14.71 CFM
Maximum Displacement at 50 Hz 12.07 CFM
Ultimate Pressure 0.75 mTorr
Ultimate Pressure with Gas Ballast 11.25 mTorr
Inlet Connection DN25 ISO-KF (NW25)
Outlet Connection 15 mm nozzle / 3/4" BSPP (G 3/4") female
Water Vapor Capacity 8.300 × 10-5 kg/s; maximum water vapor pressure 15001.23 mTorr
Nominal Rotational Speed 24.00 Hz at 50 Hz / 28.67 Hz at 60 Hz
Power Supply 1-phase 100/200 V, 50/60 Hz
Rated Power 950 W at 60 Hz / 750 W at 50 Hz
Electrical Connector IEC EN60320 C14; mates with C13 mains cable
Cooling / Noise Level Forced-air cooling / 57 dB(A)
Motor Efficiency / Protection IE2 motor / IP44 enclosure
Dimensions (L × W × H) 0.578 m × 0.180 m × 0.271 m
Weight 39.00 kg
Oil / Certifications Edwards 45 vacuum oil; UL 61010-1 3rd Ed. / CSA C22.2 No. 61010-1-12

Business Solutions & Procurement

Programs & Terms

Exclusive options for businesses and academics.

Documentation & Compliance

Keep purchasing streamlined and compliant.

Custom Solutions

Tailored vacuum equipment and integration help.

Talk to Sales

We’ll help specify the right pump for your vacuum requirements and process throughput.

FAQ

What vacuum range is supported by this Two-Stage Rotary Vane Vacuum Pump?

This two-stage rotary vane pump is designed for medium and rough vacuum applications and reaches an ultimate pressure of 0.75 mTorr. With gas ballast, the ultimate pressure is 11.25 mTorr.

What inlet and outlet connections does this 12 CFM vacuum pump use?

The pump uses a DN25 ISO-KF (NW25) inlet and a 15 mm nozzle / 3/4" BSPP (G 3/4") female outlet for connection to compatible vacuum equipment.

What oil does the Two-Stage Rotary Vane Vacuum Pump require?

The pump uses Edwards 45 vacuum oil. Typical oil volume is approximately 0.75–1.05 L, depending on configuration and service requirements.

What are the electrical requirements for the 12 CFM rotary vane vacuum pump?

The pump operates on 1-phase 100/200 V, 50/60 Hz power and is rated at 950 W at 60 Hz or 750 W at 50 Hz. It uses an IEC EN60320 C14 inlet, and some variants require hard-wiring. The mains cable is not included.

Important Shipping Notice!

DISCLAIMER:

All items are carefully packaged to ensure safe delivery. In the rare event that your item arrives damaged, please notify us within 3 days of receipt. We will promptly provide a replacement or issue a refund.

Please note that any damage occurring after delivery is not covered under warranty. We appreciate your understanding and your trust in our products.

Need Support?

We’ll get you answers fast.

Call 734-855-4890
×

Email Sales & Support

We usually reply same business day.

 
×

Technical Support

Share details and our techs will follow up.

 
×

Request a Quote

Tell us what you need and we’ll respond quickly.