BVV 4 Cylinder Butane Recovery Pump | ITS/ETL to ANSI/ISA Certified
The BVV 4 Cylinder Butane Recovery Pump is a powerful, compact recovery system designed to efficiently recover butane and propane vapor. Featuring improved Gen III pistons from RKMAC, a high-speed brushless DC motor, and oil-less reciprocating compressor technology, this pump is engineered for reliable vapor recovery with reduced contamination and efficient operation.
The BVV 4 Cylinder Butane Recovery Pump can recover up to 1 lb. of butane in approximately 0:51 seconds under specified recovery conditions. The pump is assembled in the USA with critical parts manufactured domestically, helping support long-term serviceability and parts availability. Its piston seals are rated to 450°F, while the average operating temperature is approximately 175°F.
Certified by ITS/ETL to ANSI/ISA 12.12.01, this recovery pump is designed for use in hazardous locations including Class I and II, Division 2 and Class III, Divisions 1 and 2 environments. Its computer-controlled brushless DC motor operates at approximately 3,000 RPM and provides variable-speed control for demanding butane and propane recovery applications.
Why buy from USA Lab
Engineers & technicians on staff.
Tested and trusted products.
Nationwide 1-2 day shipping.
US-based service & spares.
Why this BVV 4 Cylinder Butane Recovery Pump?
- Efficient vapor recovery — designed to process up to 10,000 lbs. of vapor recovery before rebuild under appropriate operating conditions.
- Fast recovery performance — capable of recovering 1 lb. of butane in approximately 0:51 seconds under the specified test conditions.
- Oil-less compressor design — oil-less reciprocating compressors help maintain a clean product recovery process.
- High-efficiency motor — computer-controlled brushless DC motor operates at approximately 3,000 RPM and provides variable-speed control.
- Durable sealing system — Viton O-ring seals provide compatibility with butane/propane gas and oil, while piston seals are rated to 450°F.
- USA assembled — designed and assembled in the USA using domestic and global components, with critical parts domestically made for serviceability.
- Hazardous-location certification — ITS/ETL certified to ANSI/ISA 12.12.01 for specified hazardous-location environments.
Talk to an expert
Get help matching JIC size, tubing, and gasket standards to your KF foreline.
Technical Specifications
| Specification | Details |
|---|---|
| Product Type | Butane & Propane Recovery Pump |
| Cylinder Configuration | 4-Cylinder |
| Pump Type | Oil-less Reciprocating Compressor |
| Motor Type | Brushless DC Motor |
| Motor Speed | 3,000 RPM |
| Voltage | 100-240V AC |
| Frequency | 50/60 Hz |
| Phase | 1 Phase |
| Piston Seal Temperature Rating | 450°F |
| Average Operating Temperature | 175°F |
| O-Ring Material | Viton |
| Recovery Capacity | Up to 10,000 lbs. of vapor before rebuild |
| Butane Recovery Performance | 1 lb. in approximately 0:51 seconds under specified conditions |
| Certification | ITS/ETL to ANSI/ISA 12.12.01 |
| Hazardous Location Rating | Class I & II, Division 2; Class III, Divisions 1 & 2 |
| Noise Level | 90.3 dB at 1 m |
| Manufacturer Warranty | 2 Years, including Hemp usage |
| Assembly | Assembled in the USA |
| Parts Availability | USA-made piston seal rebuild kits available |
Popular Industries & Use Cases
Business Solutions & Procurement
Exclusive options for businesses and academics.
Keep purchasing streamlined and compliant.
Tailored equipment and integration help.
We’ll help spec the right equipment for your recovery workflow.
FAQ
What is the BVV 4 Cylinder Butane Recovery Pump designed to recover?
The BVV 4 Cylinder Butane Recovery Pump is designed for butane and propane vapor recovery. Its oil-less reciprocating compressor and high-efficiency brushless DC motor support clean and efficient recovery applications.
How fast can the BVV 4 Cylinder Butane Recovery Pump recover butane?
Under the specified test conditions, the BVV 4 Cylinder Butane Recovery Pump recovered 1 lb. of butane in approximately 0:51 seconds. The stated result was achieved with a collection base pressure greater than 30 psi, a recovery cylinder pressure below 10 psi, and a dry ice coil between the pump output and recovery cylinder.
Is the BVV 4 Cylinder Butane Recovery Pump certified for hazardous locations?
Yes. The BVV 4 Cylinder Butane Recovery Pump is certified by ITS/ETL to ANSI/ISA 12.12.01 for use in specified hazardous locations, including Class I and II, Division 2 and Class III, Divisions 1 and 2 environments.
What power requirements does the BVV 4 Cylinder Butane Recovery Pump use?
The BVV 4 Cylinder Butane Recovery Pump is rated for universal voltage from 100-240V AC, 50/60 Hz, single phase. Its computer-controlled brushless DC motor operates at approximately 3,000 RPM.
Important Shipping Notice!
DISCLAIMER:
All items are carefully packaged to ensure safe delivery. In the rare event that your item arrives damaged, please notify us within 3 days of receipt. We will promptly provide a replacement or issue a refund.
Please note that any damage occurring after delivery is not covered under warranty. We appreciate your understanding and your trust in our products.
Email Sales & Support
We usually reply same business day.
Technical Support
Share details and our techs will follow up.
Request a Quote
Tell us what you need and we’ll respond quickly.