1/4" MNPT Generant Cryogenic Relief Valve - 10PSI, 22PSI, 35PSI, 50 PSI, 100PSI, 150PSI, 200PSI, 250PSI -196°C to 176°C
GenerantCRVSale $59.00 - $59.95Retail -
Generant Pipe Away Adapter for Cryogenic Relief Valve - 1/2" FNPT Outlet
GenerantCRV-12-ADAPTSale $15.00Retail -
-
Description
1/2" MNPT Generant Cryogenic Relief Valve - 25 PSI -196°C to 176°C
The Generant Series Brass CRV Cryogenic Relief Valve is a spring-referenced overpressure protection device designed for reliable pressure relief in cryogenic systems. This 1/2" MNPT valve is factory preset to 25 Psig and provides compact, high-flow protection for applications where dependable blocked-line safety is required.
The CRV incorporates Generant’s exclusive “Dirt Guard” poppet feature, which helps the valve tolerate particulate contamination while supporting reliable operation. Optimized seat and poppet geometry combined with spring ranges provide high flow capacity with minimum pressure accumulation and excellent reseat performance.
The valve is cleaned and packaged for oxygen service and supplied factory preset and permanently locked for tamper-proof operation. Relief pressure can be discharged to atmosphere or routed through downstream piping, while optional configurations such as a deflector cap can help direct exhausted gas.
25 Psig Factory Set 1/2" MNPT Cryogenic Service -196°C to 176°C
Factory Preset: 25 Psig set pressure — permanently locked to provide tamper-proof pressure protection.
Dirt Guard: Exclusive screened poppet design — helps increase tolerance to particulate contamination and support valve reliability.
Cryogenic Range: -320°F to 350°F (-196°C to 176°C) — supports demanding temperature conditions based on seal material.
Why buy from USA Lab
Expert Support
Engineers & technicians on staff.
Engineers & technicians on staff.
Quality First
Tested and trusted products.
Tested and trusted products.
Fast Fulfillment
Nationwide 1-2 day shipping.
Nationwide 1-2 day shipping.
Warranty & Parts
US-based service & spares.
US-based service & spares.
Why this Generant Cryogenic Relief Valve?
- Reliable overpressure protection — designed as a blocked-line safety device for cryogenic systems.
- High flow capacity — optimized seat and poppet geometry help provide high flow rates with minimum pressure accumulation.
- Excellent reseat performance — reseats at 90% of set pressure, with 85% performance specified for PCTFE seal sets below 100 Psig.
- Contamination tolerance — the exclusive Dirt Guard poppet incorporates a screen to help extend valve reliability.
- Oxygen-service preparation — supplied cleaned and packaged for oxygen service.
Talk to an expert
Get product guidance, application support, and compatibility information for your laboratory workflow.
Technical Specifications
| Specification | Details |
|---|---|
| Product | Generant Cryogenic Relief Valve (CRV) |
| Connection | 1/2" MNPT |
| Nominal Set Pressure | 25 Psig |
| Set Pressure Range | 0.7 to 51.7 Bar |
| Factory Set Tolerance | Per EN ISO 4126-1; varies by set-pressure range |
| Set Pressure ≤ 28.90 Psig | ±5% |
| Set Pressure 29.00–48.30 Psig | ±1.45 Psig |
| Set Pressure ≥ 48.40 Psig | ±3% |
| Zero Leakage | To 95% of set pressure |
| Body Material | Brass |
| Reseat | 90% of set pressure |
| PCTFE Reseat | 85% for PCTFE seal set below 100 Psig (6.9 Bar) |
| Temperature Rating | -320°F to 350°F (-196°C to 176°C) |
| Seal Material 10–49 Psig | Fluorosilicone |
| Seal Material 50–750 Psig | PCTFE |
| Lubricant | Krytox® |
| Oxygen Service | Cleaned and packaged for oxygen service |
Popular Industries & Use Cases
Business Solutions & Procurement
Programs & Terms
Exclusive options for businesses and academics.
Documentation & Compliance
Keep purchasing streamlined and compliant.
Custom Solutions
Tailored equipment and integration help.
Talk to Sales
We’ll help spec the right equipment for your laboratory workflow.
FAQ
What is the set pressure of the 1/2" MNPT Generant Cryogenic Relief Valve?
The 1/2" MNPT Generant Cryogenic Relief Valve is factory preset to a nominal set pressure of 25 Psig. The relief pressure is permanently locked and cannot be altered or adjusted in the field.
What temperature range does the Generant Cryogenic Relief Valve support?
The Generant Cryogenic Relief Valve has a temperature rating of -320°F to 350°F (-196°C to 176°C), based on the seal material used.
Is the Generant Cryogenic Relief Valve suitable for oxygen service?
Yes. The CRV is supplied cleaned and packaged for oxygen service, making it suitable for specified cryogenic oxygen-service applications.
What is the purpose of the Dirt Guard feature on the Generant CRV?
The exclusive Dirt Guard poppet incorporates a screen designed to increase the valve’s ability to tolerate particulate contamination and support reliable operation.
Important Shipping Notice!
DISCLAIMER:
All items are carefully packaged to ensure safe delivery. In the rare event that your item arrives damaged, please notify us within 3 days of receipt. We will promptly provide a replacement or issue a refund.
Please note that any damage occurring after delivery is not covered under warranty. We appreciate your understanding and your trust in our products.
×
Email Sales & Support
We usually reply same business day.
×
Technical Support
Share details and our techs will follow up.
×
Request a Quote
Tell us what you need and we’ll respond quickly.